Pile Testing
Pile Dynamic Analysis (PDA)
High-strain dynamic testing on driven steel pipe piles for a major interchange structure north of Riyadh.

Pile Dynamic Analysis (PDA)
Scope of work
FEG provided independent dynamic pile testing during the production driving phase. Testing was scheduled to capture end-of-drive blows and restrike events in accordance with the project specification.
Scope of work included:
Pre-mobilisation review of pile schedules, hammer systems, and acceptance criteria.
On-site PDA acquisition with calibrated accelerometers and strain transducers.
CAPWAP signal matching to estimate shaft and toe resistance components.
Comparison of measured capacity against design factored resistance.
Daily test summary and final pile capacity verification report.